Parameter Name |
BVC Flow Control Timer F |
---|---|
Description |
This parameter specifies the value of the BVC flow control timer. A flow control message is sent in the cell every time this timer expires. For example, value 1000 indicates that the timer value is 1000 ms, and value 3000 indicates that the timer value is 3000 ms. |
GUI Value Range |
[1000,3000] |
Default Value |
1000 |
Unit |
Milliseconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to an excessive value, the flow control message cannot be received in time. If this parameter is set to a modest value, the flow control message is sent frequently. |
Recommended Value |
1000 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |