BVC Flow Control Timer F

Parameter Name

BVC Flow Control Timer F

Description

This parameter specifies the value of the BVC flow control timer. A flow control message is sent in the cell every time this timer expires.

For example, value 1000 indicates that the timer value is 1000 ms, and value 3000 indicates that the timer value is 3000 ms.

GUI Value Range

[1000,3000]

Default Value

1000

Unit

Milliseconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to an excessive value, the flow control message cannot be received in time.

If this parameter is set to a modest value, the flow control message is sent frequently.

Recommended Value

1000

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Equipment

Caution

None