Parameter Name |
DTE Parameter (T391) |
---|---|
Description |
This parameter specifies the timer set to wait for a link integrity acknowledgment message. The timer is started when the link is initialized. When the timer expires, the link integrity acknowledgment message is resent. |
GUI Value Range |
[5,30] |
Default Value |
10 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If the timer is set to an excessive value, the link integrity acknowledgment message cannot be sent in time. If the timer is set to a modest value, the link integrity acknowledgment message is sent frequently and many resources are wasted. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |