Parameter Name |
Control Acknowledge Type |
---|---|
Description |
This parameter specifies the acknowledgment message type used by the MS. If four access pulses are used, the timing advance can be obtained without a polling message. If the RLC/MAC control block is used, the timing advance can be obtained only by sending a polling message. Four access pulses are recommended. |
GUI Value Range |
[Four access pulses by default,RLC/MAC control block by default] |
Default Value |
Four access pulses by default |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
Four access pulses by default |
Parameter Relationship |
None |
BSC Feature |
GPRS&EGPRS |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |