Parameter Name |
Extension MR Period(Seconds) |
---|---|
Description |
This parameter specifies the interval between two extension measurement reports. |
GUI Value Range |
[60,120,240,480,960,1920,3840,7680] |
Default Value |
60 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a modest value, the extension measurement report is sent frequently. If this parameter is set to an excessive value, measurement information is not obtained timely. |
Recommended Value |
60 |
Parameter Relationship |
None |
BSC Feature |
GPRS&EGPRS |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |