Parameter Name |
Non-DRX Period(Seconds) |
---|---|
Description |
This parameter specifies the minimum duration when the MS stays in non-DRX mode after the NC NC-measurement report is sent. The MS should stay in non-DRX mode for a period of time after the measurement report is sent. |
GUI Value Range |
[nodrx,0.24,0.48,0.72,0.96,1.20,1.44,1.92] |
Default Value |
0.24 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The MS should stay in non-DRX mode for a period of time after the measurement report is sent. If this parameter is set to an excessive value, the MS may stay in non-DRX mode for a long time and services may be affected. If this parameter is set to a modest value, the MS enters the DRX mode and may send the measurement report frequently. |
Recommended Value |
0.24 |
Parameter Relationship |
None |
BSC Feature |
GPRS&EGPRS |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |