Cell Reselection MR Period in Packet Transfer Mode(Seconds)

Parameter Name

Cell Reselection MR Period in Packet Transfer Mode(Seconds)

Description

This parameter specifies the period of cell reselection measurement report in packet transfer mode.

GUI Value Range

[0.48,0.96,1.92,3.84,7.68,15.36,30.72,61.44]

Default Value

0.96

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to an excessive value, some information may be missing.

If this parameter is set to a modest value, the reselection measurement report is sent frequently. This occupies many bandwidth resources.

Recommended Value

0.96

Parameter Relationship

None

BSC Feature

GPRS&EGPRS

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential