GPRS Cell Reselect Hysteresis(dB)

Parameter Name

GPRS Cell Reselect Hysteresis(dB)

Description

This parameter specifies the hysteresis of cell reselection in the same routing area.

When an MS in the ready state performs cell reselection, if the originating cell and the target cell belong to the same routing area, the C2 value measured in the overlapped area of two adjacent cells fluctuates greatly because of the fading feature of radio channels. Therefore, the MS frequently performs cell reselection. The frequent cell reselection not only increases the signaling flow on the network and affects the utilization of radio resources, but also greatly affects the data transmission rate of the MS and decreases the QoS as a consequence.

When this parameter is used, the MS starts cell reselection only when the signal level of the neighbor cells in the same routing area is higher than that of this cell, and when the signal level difference is greater than the value of this parameter.

If this parameter is set to an excessive value, it is hard to start cell reselection.

GUI Value Range

[0,2,4,6,8,10,12,14]

Default Value

2

Unit

dB

Step

-

Modification Rules

None

Configuration Policy

In the same routing area, if this parameter is set to an excessive value, it is hard for cell reselection. If this parameter is set to a modest value, the frequent ping-pong reselection occurs.

Recommended Value

2

Parameter Relationship

GPRS Cell Reselect Hysteresis Applied to C31 Criterion or not

BSC Feature

GPRS&EGPRS

Parameter Class

Parameters About Radio Resources

Caution

The value of this parameter should not be set to 0 dB. Otherwise, frequent cell handovers occur.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.