Cell Reselection Forbidden Time(Seconds)

Parameter Name

Cell Reselection Forbidden Time(Seconds)

Description

This parameter specifies the period when cell reselection is prohibited.

This parameter is an optional field in the information element PSI3. The value nouse indicates that this parameter will not be coded in the information element.

GUI Value Range

[5,10,15,20,30,60,120,300,nouse]

Default Value

10

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to an excessive value, the period when cell reselection is prohibited increases.

If this parameter is set to a modest value, the period when cell reselection is prohibited decreases.

Recommended Value

10

Parameter Relationship

None

BSC Feature

GPRS&EGPRS

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential