Parameter Name |
Threshold of HCS Signal Strength(dB) |
---|---|
Description |
This parameter specifies the threshold of HCS signal strength. The MS uses the signal strength in the MR and this threshold to calculate C31, which is used for cell reselection. This parameter is an optional field in the information element PSI3/PSI3bis. The value nouse indicates that this parameter will not be coded in the information element. |
GUI Value Range |
[-110,-108,-106,-104,-102,-100,-98,-96,-94,-92,-90,-88,-86,-84,-82,-80,-78,-76,-74,-72,-70,-68,-66,-64,-62,-60,-58,-56,-54,-52,-50,-48,nouse] |
Default Value |
-110 |
Unit |
dB |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If the threshold of HCS signal strength is high, it is difficult for the cell to be selected. If the threshold of HCS signal strength is low, it is easy for the cell to be selected. |
Recommended Value |
-110 |
Parameter Relationship |
None |
BSC Feature |
GPRS&EGPRS |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |