Cell Penalty Level

Parameter Name

Cell Penalty Level

Description

This parameter specifies the signal level for target cell penalty after the BSC receives the cell reselection failure message or after the cell initiates the load-based reselection. This parameter is valid only within the Cell Penalty Last Time.

GUI Value Range

[0,63]

Default Value

30

Unit

None

Step

-

Modification Rules

None

Configuration Policy

If the value of this parameter increases, the MS can be handed over to the target cell only if the target cell has a higher level; conversely, the MS can be handed over to the target cell only if the target cell has a lower level.

Recommended Value

30

Parameter Relationship

None

BSC Feature

NC2

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential