Parameter Name |
Normal Cell Reselection Watch Period |
---|---|
Description |
This parameter specifies the number of times that the receive levels of the serving cell are continuously calculated before the P/N criterion is determined. |
GUI Value Range |
[1,32] |
Default Value |
10 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to a lower value, the precision of decision may be reduced; if this parameter is set to a higher value, the decision may not be performed immediately. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
NC2 |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |