Parameter Name |
DSP Kickoff Timer |
---|---|
Description |
This parameter specifies the time waiting for the recovery of all the DSPs. This timer is started when the first DSP recovers. When all the DSPs in the subrack recover or the timer expires, the timer is stopped and cells are distributed on the DSPs recovered. For example, value 1 specifies that the time length is one second, and value 3600 specifies that the time length is 3600 seconds. |
GUI Value Range |
[1,3600] |
Default Value |
180 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If the parameter is set to a lower value, there may be very few DSPs recovered. Therefore, the DSP resources used for cell distribution are few; if the parameter is set to a higher value, the waiting time is too long if some DSPs are faulty. |
Recommended Value |
180 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |