Parameter Name |
TA HO Watch Time(Num of MR)(0.5s) |
---|---|
Description |
The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. Every 0.48s a measurement report is submitted. Therefore, the unit is 0.5s. This parameter corresponds to N in the P/N criterion. |
GUI Value Range |
[1,16] |
Default Value |
1 |
Unit |
Seconds |
Step |
0.5s |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
1 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter is valid only when the HO Control Switch is set to HO Algorithm II. This parameter is invalid when the HO Control Switch is set to HO Algorithm I. |