TA HO Valid Time(0.5s)

Parameter Name

TA HO Valid Time(0.5s)

Description

The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. Measurement reports are submitted every 0.48s. Therefore, the unit here is set to 0.5s.

This parameter corresponds to P in the P/N criterion.

GUI Value Range

[1,16]

Default Value

1

Unit

Seconds

Step

0.5s

Modification Rules

None

Configuration Policy

None

Recommended Value

1

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

This parameter is valid only when the HO Control Switch is set to HO Algorithm II. This parameter is invalid when the HO Control Switch is set to HO Algorithm I.


Huawei Proprietary and Confidential