Parameter Name |
Interfere HO Valid Time(0.5s) |
---|---|
Description |
The P/N criterion must be met for triggering an interference handover. That is, the interference handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. Measurement reports are submitted every 0.48s. Therefore, the unit here is set to 0.5s. This parameter corresponds to P in the P/N criterion. |
GUI Value Range |
[1,16] |
Default Value |
2 |
Unit |
Seconds |
Step |
0.5s |
Modification Rules |
None |
Configuration Policy |
None |
Recommended Value |
2 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
None |