Interfere HO Valid Time(0.5s)

Parameter Name

Interfere HO Valid Time(0.5s)

Description

The P/N criterion must be met for triggering an interference handover. That is, the interference handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. Measurement reports are submitted every 0.48s. Therefore, the unit here is set to 0.5s.

This parameter corresponds to P in the P/N criterion.

GUI Value Range

[1,16]

Default Value

2

Unit

Seconds

Step

0.5s

Modification Rules

None

Configuration Policy

None

Recommended Value

2

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None