Parameter Name |
Penalty Time on Load HO |
---|---|
Description |
After a load handover is successfully performed, the BSC gives a penalty to the original serving cell, that is, subtracts the Penalty Value on Load HO from the level of the original serving cell during the Penalty Time on Load HO. |
GUI Value Range |
[0,255] |
Default Value |
10 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The greater the value of this parameter, the longer the penalty is given to the original cell and the more difficult the call is to be handed over to the original cell. |
Recommended Value |
10 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |