IntraCell TCHF-TCHH Ho Period(s)

Parameter Name

IntraCell TCHF-TCHH Ho Period(s)

Description

The value range of this parameter is the same as that of IntraCell TCHF-TCHH Ho Duration(s), and the value of this parameter must be smaller than that of IntraCell TCHF-TCHH Ho Duration(s).

GUI Value Range

[0,600]

Default Value

1

Unit

Seconds

Step

-

Modification Rules

None

Configuration Policy

If this parameter is set to a too small value, the handover zone is enlarged in a short time, and thus many MSs are handed over from TCHF to TCHH.

If this parameter is set to a too great value, the handover zone is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, network congestion cannot be relieved in time.

Recommended Value

1

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

This parameter is available only when HO Control Switch is set to HO Algorithm II. This parameter is invalid when the HO Control Switch is set to HO Algorithm I.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.