Parameter Name |
IntraCell TCHH-TCHF Ho Last Time(s) |
---|---|
Description |
This parameter indicates that if the IntraCell TCHH-TCHF Ho Last Time meets the conditions for triggering AMR TCHF-TCHH handover within the IntraCell TCHF-TCHH Ho Stat. Time, the AMR TCHF-TCHH switchover is triggered. This parameter, used with IntraCell TCHH-TCHF Ho Stat Time(s), equals the P values defined in the P/N criterion. If the IntraCell TCHF-TCHH Ho Last Time meets the conditions for triggering AMR TCHF-TCHH handover within the IntraCell TCHF-TCHH Ho Stat. Time, the AMR TCHF-TCHH handover is triggered. |
GUI Value Range |
[1,16] |
Default Value |
2 |
Unit |
Seconds |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set too large, the MS takes a longer time to meet the conditions for triggering the AMR TCHH-TCHF handover. As a result, the AMR TCHH-TCHF handover cannot be performed immediately and the speech quality unnecessarily deteriorates. If this parameter is set too small, the MS takes a shorter time to meet the conditions for triggering the AMR TCHH-TCHF handover. As a result, the AMR TCHH-TCHF handover might incur a wrong decision. |
Recommended Value |
2 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Radio Resources |
Caution |
This parameter can be configured only when HO Control Switch is set to HO Algorithm II; this parameter is invalid when HO Control Switch is set to HO Algorithm I. |