Flow Control Stop Threshold

Parameter Name

Flow Control Stop Threshold

Description

This parameter specifies the threshold of stopping flow control on the LAPD link. That is, when the proportion of I frames to those allowed in the LAPD I frame queue is lower than the parameter value, the system stops flow control on the LAPD link.

GUI Value Range

[0,100]

Default Value

60

Unit

%

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

60

Parameter Relationship

The flow control stop threshold must be smaller than the flow control start threshold.

BSC Feature

None

Parameter Class

Parameters About Transmission

Caution

None


Huawei Proprietary and Confidential