Unsuccessful VBS Assignment (Other Causes)

Measurement Counter

A03431: CELL_VBS_ASS_FAIL_OTHER

Description

This measurement provides the number of assignment failures due to incorrect channel type, channel rate, or speech coding algorithm in the VBS ASSIGNMENT REQUEST message that the BSC receives from the MSC.

Unit

Integer number or integer.

Measurement Point

This counter is incremented by one when the BSC finds that the channel type, channel rate, or speech coding algorithm in the VBS ASSIGNMENT REQUEST message received from the MSC is incorrect.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.