A03449: CELL_VGCS_UL_CALL_DROP
When the MS initiates a request for the uplink TCH, a call drop may occur. This measurement provides the number of call drops when the MS in the cell seizes the uplink TCH.
Integer number or integer.
This counter is incremented by one when the BSC receives a CONNECTION FAILURE INDICATION or ERROR INDICATION message. In the signaling procedure, this counter is measured at point A in Figure 1.
This is an original counter without involving any formula.