A03515: CELL_GCC_HO_SUCC_TA
This measurement provides the number of successful VGCS TCH handovers caused by timing advance.
Integer number or integer.
(1) In the case of the intra-BSC intra-cell handover, this counter is incremented by one when the originating BSC receives a HANDOVER SUCCEEDED message from the MSC. The measurement point is B, as shown in Figure 1.
(2) In the case of the intra-BSC inter-cell handover, this counter is incremented by one when the target cell receives a HANDOVER COMPLETE message from the BTS. The measurement point is B, as shown in Figure 2.
(3) In the case of the inter-BSC handover, this counter is incremented by one when the originating BSC receives a HANDOVER SUCCEEDED message from the MSC. The measurement point is B, as shown in Figure 3.
This is an original counter without involving any formula.