A3157A: CELL_CHMD_FAIL_MOC_TCHF
A3157C: CELL_CHMD_FAIL_MTC_TCHF
A3157D: CELL_CHMD_FAIL_ECALL_TCHF
A3157E: CELL_CHMD_FAIL_CALL_REEST_TCHF
A3158A: CELL_CHMD_FAIL_MOC_TCHH
A3158C: CELL_CHMD_FAIL_MTC_TCHH
A3158E: CELL_CHMD_FAIL_CALL_REEST_TCHH
A3159E: CELL_CHMD_FAIL_NO_CIC
A3159F: CELL_CHMD_FAIL_CIC_ALLOC
A3159B: CELL_CHMD_FAIL_APPLY_TRSL_FAIL
A3159G: CELL_CHMD_FAIL_A_INTF_FAIL
A3159H: CELL_CHMD_FAIL_MSC_CLR_CMD
A3159C: CELL_CHMD_FAIL_EXP
A3159I: CELL_CHMD_FAIL_NO_SPEECH_VER
The counters indicate the numbers of failed Mode Modify attempts that ultimately caused failed assignments due to various reasons after the BSC sends a CHAN MODE MODIFY message to the MS.
A3159E: CELL_CHMD_FAIL_NO_CIC
The counter A3159E provides the number of ASS FAIL messages sent by the BSC to the MSC after the BSC finds that the received ASS REQ message carries an unavailable A interface CIC when the BSC uses the Mode Modify procedure to complete the assignment procedure.
A3159F: CELL_CHMD_FAIL_CIC_ALLOC
The counter A3159F provides the number of ASS FAIL messages sent by the BSC to the MSC after the BSC finds that the received ASS REQ message carries an A interface CIC that is already occupied by another call when the BSC uses the Mode Modify procedure to complete the assignment procedure.
A3159B: CELL_CHMD_FAIL_APPLY_TRSL_FAIL
The counter A3159B provides the number of ASS FAIL messages sent by the BSC to the MSC after the MS drops from the connection to the air interface, or a circuit fails to be obtained for the call, or the obtained circuit is faulty during the circuit connection of the BSC when the BSC uses the Mode Modify procedure to complete the assignment procedure.
A3159G: CELL_CHMD_FAIL_A_INTF_FAIL
The counter A3159G provides the number of times that the BSC locally releases the call after receiving an SS7 link abnormality indication when the BSC uses the Mode Modify procedure to complete the assignment procedure.
The following counter indicates the number of failed Mode Modify attempts due to the call clearing performed by the MSC.
A3159H: CELL_CHMD_FAIL_MSC_CLR_CMD
The counter A3159H provides the number of times that the BSC releases the call after receiving a CLEAR CMD message from the MSC when the BSC uses the Mode Modify procedure to complete the assignment procedure.
The following counter indicates the number of failed Mode Modify attempts due to the failure of air interface access.
A3159C: CELL_CHMD_FAIL_EXP
The counter A3159C provides the number of ASS FAIL messages sent by the BSC to the MSC after the timer for the BSC to wait for a CHAN MODE MODIFY ACK message expires when the BSC uses the Mode Modify procedure to complete the assignment procedure.
The following counter indicates the number of failed Mode Modify attempts due to abnormal allocation of air interface resources.
A3159I: CELL_CHMD_FAIL_NO_SPEECH_VER
The counter A3159I provides the number of ASS FAIL messages sent by the BSC to the MSC when the Mode Modify fails because the intersection between the speech version set carried in the ASS REQ message from the MSC and the speech version set supported by the current cell of the MS does not have available speech versions when the BSC uses the Mode Modify procedure to complete the assignment procedure.
Integer number or integer.
This is an original counter without involving any formula.