Number of Paging Messages Sent on the PCH in the First Scheduling Period

Measurement Counter

A344: CELL_PCH_MSG_NUM_Frst_CYCLE

Description

This measurement provides the number of paging messages in the first paging cycle, if the delay between the PCH scheduling time and the PCH message receive time is within one paging cycle. The BTS measures the value of the CELL_QUE_OCCUPY_PK_VALUE and reports it in the BTS_STATIS_REPORT message to the BSC.

Unit

Integer number or integer

Measurement Point

If the BSC receives the BTS_STATIS_REPORT message from the BTS and decodes the information element CELL_PCH_MSG_NUM_Frst_CYCLE from the message, this counter is incremented at C1 as shown in Figure 1.

Figure 1 Procedure for the BTS sending the BTS_STATIS_REPORT message

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.