Average Busy Time of Tsn

Measurement Counters

AL0001:BS_A_INTFACE_BUSY_TS1_SUMAVR

AL0002:BS_A_INTFACE_BUSY_TS2_SUMAVR

AL0003:BS_A_INTFACE_BUSY_TS3_SUMAVR

AL0004:BS_A_INTFACE_BUSY_TS4_SUMAVR

AL0005:BS_A_INTFACE_BUSY_TS5_SUMAVR

AL0006:BS_A_INTFACE_BUSY_TS6_SUMAVR

AL0007:BS_A_INTFACE_BUSY_TS7_SUMAVR

AL0008:BS_A_INTFACE_BUSY_TS8_SUMAVR

AL0009:BS_A_INTFACE_BUSY_TS9_SUMAVR

AL0010:BS_A_INTFACE_BUSY_TS10_SUMAVR

AL0011:BS_A_INTFACE_BUSY_TS11_SUMAVR

AL0012:BS_A_INTFACE_BUSY_TS12_SUMAVR

AL0013:BS_A_INTFACE_BUSY_TS13_SUMAVR

AL0014:BS_A_INTFACE_BUSY_TS14_SUMAVR

AL0015:BS_A_INTFACE_BUSY_TS15_SUMAVR

AL0016:BS_A_INTFACE_BUSY_TS16_SUMAVR

AL0017:BS_A_INTFACE_BUSY_TS17_SUMAVR

AL0018:BS_A_INTFACE_BUSY_TS18_SUMAVR

AL0019:BS_A_INTFACE_BUSY_TS19_SUMAVR

AL0020:BS_A_INTFACE_BUSY_TS20_SUMAVR

AL0021:BS_A_INTFACE_BUSY_TS21_SUMAVR

AL0022:BS_A_INTFACE_BUSY_TS22_SUMAVR

AL0023:BS_A_INTFACE_BUSY_TS23_SUMAVR

AL0024:BS_A_INTFACE_BUSY_TS24_SUMAVR

AL0025:BS_A_INTFACE_BUSY_TS25_SUMAVR

AL0026:BS_A_INTFACE_BUSY_TS26_SUMAVR

AL0027:BS_A_INTFACE_BUSY_TS27_SUMAVR

AL0028:BS_A_INTFACE_BUSY_TS28_SUMAVR

AL0029:BS_A_INTFACE_BUSY_TS29_SUMAVR

AL0030:BS_A_INTFACE_BUSY_TS30_SUMAVR

AL0031:BS_A_INTFACE_BUSY_TS31_SUMAVR

Description

The counters AL00n:BS_A_INTFACE_BUSY_TSn_SUMAVR provide the average busy time of timeslot n during a certain period, that is, the average time of timeslot n used in the transmission of speech signals during the granularity period.

(01 <= n <= 31)

Unit

s.

Measurement Point

The BSC measures the sampled status data of each timeslot (timeslot 1 to timeslot 31). The average busy time of a timeslot can be obtained by dividing the total busy time of the timeslot by the number of times that the timeslot is busy.

Formula

Average Busy Time of TSn = [Total Busy Time of TSn]/[Number of Times When TSn Is Busy]


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.