AL0053:BS_A_INTF_CONG_CIC_AVG
This measurement provides the average number of Blocked Circuits on the A Interface.
Integer number or integer.
The BSC measures the number of blocked circuits on the A interface every 10 seconds.
This counter is measured by using the following formula.
Mean Number of Blocked Circuits on the A Interface = [Sampling Number of Blocked Circuits on the A Interface]/({GP} x {6})
GP: Granularity Period. (Unit: minute)