Mean Number of Blocked Circuits on the A Interface

Measurement Counter

AL0053:BS_A_INTF_CONG_CIC_AVG

Description

This measurement provides the average number of Blocked Circuits on the A Interface.

Unit

Integer number or integer.

Measurement Point

The BSC measures the number of blocked circuits on the A interface every 10 seconds.

This counter is measured by using the following formula.

Formula

Mean Number of Blocked Circuits on the A Interface = [Sampling Number of Blocked Circuits on the A Interface]/({GP} x {6})

GP: Granularity Period. (Unit: minute)


Huawei Proprietary and Confidential