Mean Number of Circuits with Uninstalled Peer Circuits on the A Interface

Measurement Counter

AL0089:BS_A_INTF_PEER_UNINST_CIC_AVG

Description

This measurement provides the average number of circuits with uninstalled peer circuits on the A interface.

Unit

Integer number or integer.

Measurement Point

The BSC measures the number of circuits whose peer circuits are uninstalled on the A interface every 10 s.

This counter is measured by the using the following formula.

Formula

Mean Number of Circuits with Uninstalled Peer Circuits on the A Interface = [Sampling Number of A Circuits with Uninstalled Peer Circuits on the A Interface]/({GP} x {6})

GP: Granularity Period. (Unit: minute)


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.