AR3011A:CELL_CH_NUM_PDCH_900_AVR
AR3011B:CELL_CH_NUM_PDCH_1800_AVR
CR3011:CELL_CH_NUM_PDCH_AVR
AR3011A:CELL_CH_NUM_PDCH_900_AVR provides the mean number of the configured PDCHs in the GSM900, GSM900/DCS1800, GSM850, GSM850/DCS1800, and GSM850/PCS1900 cells controlled by the BSC in the granularity period. This number includes the number of the PDCHs that are converted from dynamic PDCHs.
AR3011B:CELL_CH_NUM_PDCH_1800_AVR provides the mean number of configured PDCHs in the DCS1800 and PCS1900 cells controlled by the BSC in the granularity period. This number includes the number of PDCHs that are converted from dynamic PDCHs.
CR3011:CELL_CH_NUM_PDCH_AVR provides the mean number of configured PDCHs in the cells on all frequency bands controlled by the BSC in real-time measurement. This number includes the number of PDCHs that are converted from dynamic PDCHs.
Integer number or integer.
In the granularity period, the counters are calculated as follows.
Mean Number of Dynamically Configured Channels (PDCH) (900/850 Cell) = Total Number of Dynamically Configured Channels (PDCH) (900/850 Cell)/Number of Sampling Times
Mean Number of Dynamically Configured Channels (PDCH) (1800/1900 Cell) = Total Number of Dynamically Configured Channels (PDCH) (1800/1900 Cell)/Number of Sampling Times
Mean Number of Available Channels (PDCH) = Mean Number of Available Channels (PDCH) (900/850 Cell) + Mean Number of Available Channels (PDCH) (1800/1900 Cell)