AS3101: CELL_VOICE_ACT COMP_RATE
This measurement provides the compression rate of active voice frames.
None.
In the granularity period, this counter is calculated according to the following formula.
VAC Compress Rate of Cell =
([Number of Uplink Frames with FR AMR of 4.75 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 5.15 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 5.90 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 6.70 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 7.40 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 7.95 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 10.20 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with HR AMR of 4.75 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with HR AMR of 5.15 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with HR AMR of 5.90 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with HR AMR of 6.70 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with HR AMR of 7.40 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames with FR AMR of 12.20 kbit/s in the Customized MR of Cell]
+ [Number of Uplink Frames Among the FR Frames in the Customized MR of Cell]
+ [Number of Uplink Frames Among the EFR Frames in the Customized MR of Cell]
+ [Number of Uplink Frames Among the HR Frames in the Customized MR of Cell])/(([Duration of Busy State for Channels (TCHF)] + [Duration of Busy State for Channels (TCHH)]) x 50)