AS3240:CELL_MS_PWR_LEV_AVR
AS3241:CELL_BTS_PWR_LEV_AVR
The counters provide the average transmit power of the MS and the BTS in the cell. When the BSC receives a MR or pre-processed MR from the BTS, the transmit power rank of the MS and the BTS are accumulated. At the end of a granularity period, the accumulated numbers are divided by the number of MRs. Then, the counters are obtained. Lower average transmit power rank suggests higher transmit power.
Integer number or integer.
In the granularity period, this counter is calculated according to the following formula.
The Average Power Level of MS = [MS Power Rank]/[Number of Power Control Messages]
The Average Power Level of BTS = [BTS Power Rank]/[Number of Power Control Messages]