Analyzed Measurement of Power Level in the MR

Measurement Counter

AS3240:CELL_MS_PWR_LEV_AVR

AS3241:CELL_BTS_PWR_LEV_AVR

Description

The counters provide the average transmit power of the MS and the BTS in the cell. When the BSC receives a MR or pre-processed MR from the BTS, the transmit power rank of the MS and the BTS are accumulated. At the end of a granularity period, the accumulated numbers are divided by the number of MRs. Then, the counters are obtained. Lower average transmit power rank suggests higher transmit power.

Unit

Integer number or integer.

Measurement Point

In the granularity period, this counter is calculated according to the following formula.

Formula

The Average Power Level of MS = [MS Power Rank]/[Number of Power Control Messages]

The Average Power Level of BTS = [BTS Power Rank]/[Number of Power Control Messages]


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.