Analyzed Measurement of Signal Quality

Measurement Counter

AS326B:CELL_DL_SIG_QLTY_AVR

AS326A:CELL_UL_SIG_QLTY_AVR

Description

The counters provide the average uplink receive quality and downlink receive quality of the cell. When the BSC receives a MR or pre-processed MR from the BTS, the uplink receive quality and downlink receive quality contained in the MR are accumulated. At the end of a granularity period, the two accumulated numbers are divided by the number of MRs. Then, the two counters are obtained. The receive quality rank ranges from 0 to 7. Lower rank suggests better quality.

Unit

Integer number or integer.

Measurement Point

In the granularity period, this counter is calculated according to the following formula.

Formula

Mean Quality of Downlink Signals = [Quality of Downlink Signals]/[Number of Power Control Messages]

Mean Quality of Uplink Signals = [Quality of Uplink Signals]/[Number of Power Control Messages]