CH332C:CELL_INTERBSC_OUTCELL_HO_FAIL_T8_EXP
During the outgoing external inter-cell handover procedure, the timer T8 starts after the BSC sends the HO CMD to the MS. This measurement provides the number of failed outgoing external inter-cell handovers due to the expiration of T8. The originating channel of the handovers excluding directed retry can be the signaling channels (SDCCH/TCHF/TCHH) and traffic channels (TCHF/TCHH). The outgoing external inter-cell handovers triggered by directed retry are also included.
Integer number or integer.
After sending the HO CMD message to the MS, the BSC starts the T8 to wait for the CLEAR CMD message from the MSC. As shown in Figure 1 and Figure 2, the counter is measured at D when T8 expires.
Failed Outgoing External Inter-Cell Handovers (T8 Expired) = [Failed Outgoing External Inter-Cell Handovers (T8 Expiry) (SDCCH) (Excluding Directed Retry)] +
[Failed Outgoing External Inter-Cell Handovers (T8 Expiry) (TCHF) (Signaling Channel)] +
[Failed Outgoing External Inter-Cell Handovers (T8 Expiry) (TCHH) (Signaling Channel)] +
[Failed Outgoing External Inter-Cell Handovers (T8 Expired) (TCHF) (Traffic Channel)] +
[Failed Outgoing External Inter-Cell Handovers (T8 Expired) (TCHH) (Traffic Channel)] +
[Failed Outgoing External Inter-Cell Handovers (T8 Expired) (Directed Retry)]