Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC)

Measurement Counter

CH352H:CELL_INTERRAN_OUTCELL_HO_FAIL_MSC_CLR

Description

This counter provides the number of failed outgoing inter-RAT inter-cell handovers because the BSC receives a CLEAR CMD message from the MSC and the Cause is not Handover successful. The Cause contained in the CLEAR CMD message can be:
  • Radio interface message failure
  • Radio interface failure
  • OM intervention
  • Equipment failure
  • Preemption
  • Invalid message
  • Protocol error between BSS and MSC
  • Other causes

Unit

Integer number or integer.

Measurement Point

At point E, as shown in Figure 1 and Figure 2, the counter is measured when the BSC receives the CLEAR CMD message from the MSC and the Cause is not Handover successful.

Figure 1 Measurement of the counters related to failed outgoing inter-RAT inter-cell handover (excluding directed retry)

Figure 2 Measurement of the counters related to failed outgoing inter-RAT inter-cell handover (directed retry)

Formula

Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) = [Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Radio Interface Message Failure)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Radio Interface Failure)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (OM Intervention)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Equipment Failure)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Preemption)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Invalid Message)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Protocol Error between BSS and MSC)] +

[Failed Outgoing Inter-RAT Inter-Cell Handovers (Clear Commands Sent By MSC) (Other Causes)]


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.