CH370a:CELL_INTRABSC_OUTCELL_HO_SUCC_BSC_LOOP
This measurement provides the total number of intra-BSC outgoing cell handover successes during BSC loop. The counter is calculated by subtracting the Failed Outgoing Internal Inter-Cell Handovers (BSC LOOP) from the Outgoing Internal Inter-Cell Handover Requests (BSC LOOP).
Integer number or integer.
As shown in Figure 1 and Figure 2, this counter is measured at D when the BSC receives the HO CMP message from the MS in the target cell during the outgoing internal inter-cell handover (BSC LOOP).
A |
Measurement point of Outgoing Internal Inter-Cell Handover Requests (Excluding Directed Retry) |
B |
Measurement point of Outgoing Internal Inter-Cell Handover Commands (Excluding Directed Retry) |
C |
Measurement point of Outgoing Internal Inter-Cell Handover Detection Messages Received by BSC (Excluding Directed Retry) |
D |
Measurement point of Successful Outgoing Internal Inter-Cell Handovers (Excluding Directed Retry) |
A |
Measurement point of Outgoing Internal Inter-Cell Handover Requests (Directed Retry) |
B |
Measurement point of Outgoing Internal Inter-Cell Handover Commands (Directed Retry) |
C |
Measurement point of Outgoing Internal Inter-Cell Handover Detection Messages Received by BSC (Directed Retry) |
D |
Measurement point of Successful Outgoing Internal Inter-Cell Handovers (Directed Retry) |
Number of Intra-BSC Outgoing Cell Handover Successes During BSC Loopback = [Outgoing Internal Inter-Cell Handover Requests (BSC LOOP)] - [Failed Outgoing Internal Inter-Cell Handovers (BSC LOOP)]