CM360:CELL_SIG_STATIC_STATE_CALL_DROPS
This measurement provides the number of calls released because of the ERR IND, CONN FAIL IND, and REL IND messages received by the BSC after the MS seizes a signaling channel.
The MS seizes a signaling channel in any of the following conditions:
In the immediate assignment procedure, the BTS sends an EST IND message to the BSC.
The MS sends a HO CMP message to the BSC, and the MS seizes a signaling channel.
Integer number or integer.
When a signaling channel is seized during a call, this counter is measured in the following situations:
1. The BSC receives an ERROR INDICATION message from the BTS because of the abnormal connection on the radio link layer. For details, refer to GSM Rec. 08.58.
2. The BSC receives a CONNECTION FAILURE INDICATION message from the BTS because of link fault or hardware fault on the radio link layer. For details, refer to GSM Rec. 08.58.
3. When receiving a DISC frame on a link layer connection in multi-frame mode, the BTS sends a REL IND message to the BSC. For details, refer to GSM Rec. 08.58.
This counter is calculated at A1, A2, and A3, as shown in Figure 1.
A1: Call Drops Due to ERR IND Received in Stable State, Call Drops Due to the ERR IND Received on the TRX in the Underlaid Subcell in Stable State, Call Drops Due to the ERR IND Received on the TRX in the Overlaid Subcell in Stable State |
A2: Call Drops Due to the CONN FAIL IND Received in Stable State, Call Drops Due to the CONN FAIL IND Received on the TRX in the Underlaid Subcell in Stable State, Call Drops Due to the CONN FAIL IND Received on the TRX in the Overlaid Subcell in Stable State |
A3: Call Drops Due to REL IND Received in Stable State, Call Drops Due to the REL IND Received on the TRX in the Underlaid Subcell in Stable State, Call Drops Due to the REL IND Received on the TRX in the Overlaid Subcell in Stable State |
A4: Call Drops Due to No MRs from MS for a Long Time, Call Drops Due to No MR from the MS on the TRX in the Underlaid Subcell, Call Drops Due to No MR from the MS on the TRX in the Overlaid Subcell, Call Drops due to Abis Terrestrial Link Failure, Call Drops Due to Abis Terrestrial Link Failure on the TRX in the Underlaid Subcell, Call Drops Due to Abis Terrestrial Link Failure on the TRX in the Overlaid Subcell, Call Drops Due to Equipment Failure, Call Drops Due to TRX Failure in the Underlaid Subcell, Call Drops Due to TRX Failure in the Overlaid Subcell, Call Drops due to Resource Check, Call Drops Due to Resource Check on the TRX in the Underlaid Subcell, Call Drops Due to Resource Check on the TRX in the Overlaid Subcell |
A5: Clear Requests Sent on the A Interface |
A6: Call Drops Due to Forced Handover, Call Drops Due to Forced Handover on the TRX in the Underlaid Subcell, Call Drops Due to Forced Handover on the TRX in the Overlaid Subcell |
A10: Successful SDCCH Seizures (Call Type) |
Call Drops on Radio Interface in Stable State (Signaling Channel) =
[Call Drops on Signaling Channel in Stable State (Error Indication)] +
[Call Drops on Signaling Channel in Stable State (Connection Failure)] +
[Call Drops on Signaling Channel in Stable State (Release Indication)]