Number of Successful Outgoing Internal Inter-Cell Handovers (Underlaid to Underlaid)

Measurement Counter

H313OO: CELL_INBSC_OUT_CELL_HO_SUCC_ULCELL_ULCELL

Description

When an internal concentric cell handover is performed, the performance of the handover between different concentric cells is measured. This measurement provides the number of successful handovers from the underlaid subcell of the originating cell to the underlaid subcell of the target cell. The measurement is performed on the basis of the originating cell and covers the handover between traffic channels, handover between signaling channels, and directed retry.

Unit

Integer number or integer.

Measurement Point

None.

Formula

Number of Successful Outgoing Internal Inter-Cell Handovers (Underlaid to Underlaid) = [Number of Outgoing Internal Inter-Cell Handovers Commands (Underlaid to Underlaid)] - [Number of Failed Outgoing Internal Inter-Cell Handovers (Underlaid to Underlaid)]


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.