Number of Successful Incoming Internal Inter-Cell Handovers (Underlaid to Underlaid)

Measurement Counter

H323OO: CELL_INBSC_INTO_CELL_HO_SUCC_ULCELL_ULCELL

Description

When a handover between different concentric cells is performed under the same BSC, the performance of the handover is measured. Taking the target cell as the measurement object, this measurement provides the number of successful handovers from the underlaid subcell of the originating cell to the underlaid subcell of the target cell. The handovers involve the handover between traffic channels, handover between signaling channels, and directed retry.

Unit

Integer number or integer.

Measurement Point

None.

Formula

Number of Successful Incoming Internal Inter-Cell Handovers (Underlaid to Underlaid) = [Number of Incoming Internal Inter-Cell Handover Commands (Underlaid to Underlaid)] - [Number of Failed Incoming Internal Inter-Cell Handovers (Underlaid to Underlaid)]


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.