Available TCHs

Measurement Counter

K3015: CELL_KPI_TCH_AVAIL_NUM

Description

This measurement provides the number of available TCHs in a cell in the BSC, that is, the BSC calculates the average number of idle TCHs or busy TCHs at each sampling point in a granularity period. The sampling period is 5s.

The TCHs include the TCHs that are converted from dynamic PDCHs but exclude the TCHs that are dynamically converted to SDCCHs.

Unit

Integer number or integer.

Measurement Point

For details, see Measurement Point in Mean Number of Available Channels (TCH).

Formula

Available TCHs = [Mean Number of Available Channels (TCH)]


Huawei Proprietary and Confidential