Average Rate for Receiving Messages on an HDLC Channel

Measurement Counter

L01009:BSC_PIU_HDLCCHANNEL_AVERECEIVE_RATE

Description

This measurement provides the average rate for receiving messages on an HDLC channel in a granularity period. After the measurement is started, the BSC measures the rate of the HDLC channel every 15 seconds.

Unit

bit/s.

Measurement Point

This counter is measured after the data is received on an HDLC channel.



Formula

Ave (RecvData/HDLC_STATS_PFM_TIMER)

RecvData: indicates the number of bytes (data) received on an HDLC channel in a period of HDLC_STATS_PFM_TIMER (15s by default).

HDLC_STATS_PFM_TIMER: indicates the period in which the BSC performs the HDLC rate measurement. The default value is 15s.

BSC_PIU_HDLCCHANNEL_AVERECEIVE_RATE: indicates the average receive rate in a granularity period.


Huawei Proprietary and Confidential