L5015:Q921_UI_RX
This measurement provides the number of UI frames received by the LAPD link.
Integer number or integer.
The measurement point is on the BSC side, as shown in the figure.
This counter is measured when the LAPD link receives UI frames sent from the BTS or the PCU.
This is an original counter without involving any formula.