M3020C: CELL_SD_CALL_DROPS_QUAL
This measurement provides the number of call drops on the SDCCH of a cell. The causes of the call release are air interface fault, no measurement report from the MS for a long time, Abis interface fault, equipment fault, and forced handover.
If the TA value is smaller than the maximum TA value of the current cell, and if the uplink receive level is greater than the Uplink Received Level Threshold of SDCCH Call Drop Statistic or if the downlink receive level is greater than the Downlink Received Level Threshold of SDCCH Call Drop Statistic, but the uplink receive quality x 10 is greater than the Uplink Quality Threshold of SDCCH Call Drop Statistic or the downlink receive quality x 10 is greater than the Downlink Quality Threshold of SDCCH Call Drop Statistic, then the counter, Call Drops on SDCCH (Receive Quality), is incremented by one.
Integer number or integer.
This is an original counter without involving any formula.