Call Drops Due to Error Indications in Stable BSC Loopback State

Measurement Counter

M3700:CELL_CALL_DROPS_ERR_IND_BSC_LOOP

Description

After seizing a channel, the MS is in the intra-BSC local switching state. The BTS sends the BSC the ERR IND message due to the abnormal connection at the radio link layer, indicating that call drops occur on the Um interface because of the faulty radio links. This measurement provides the number of call drops when the cause value carried in the ERR IND message is timer T200 expired (N200+1), times (0x01), unsolicited DM response (0x04), or sequence error (0x07).

Unit

Integer number or integer.

Measurement Point

If the BSC receives an ERR IND message, the BSC regards it as a call drop. The release procedure is started. If the MS is detected in the BSC local switch state, this counter is measured.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.