R3127C:CELL_INTRACELL_HO_CH_ALLOC_FAIL_TIMES_FR
R3128C:CELL_INTRACELL_HO_CH_ALLOC_FAIL_TIMES_HR
The previous counters are used to measure the channel assignment failures due to busy or unconfigured channels when the BSC assigns the TCHFs or TCHHs in the internal intra-cell handover procedure.
Integer number or integer.
In the internal intra-cell handover procedure, these counters are measured in either of the following cases:
The assignment fails when the assignment of TCHF, TCHH, TCHF or TCHH is requested in the following mechanisms:
TCHF preferred
TCHH preferred
The assignment succeeds but the channel is not the requested one.
This is an original counter without involving any formula.