R4110C:TRX_INTRACELL_HO_CH_ALLOC_SUCC_TIMES_SD
R4117C:TRX_INTRACELL_HO_CH_ALLOC_SUCC_TIMES_FR
R4118C:TRX_INTRACELL_HO_CH_ALLOC_SUCC_TIMES_HR
In the internal intra-cell handover procedure during which the MS is handed over between different channels in the serving cell, the BSC determines the channel type of this handover according to following items:
Handover type
Supporting capability of the circuit pool where the A interface is located
Type of the channel that is seized by the call
Channel rate and channel type requested by the MSC during the initial establishment of the call
The previous Items are measured after the BSC successfully assigns the channels.
Integer number or integer.
In the internal intra-cell handover procedure, the BSC successfully assigns the corresponding channels after the request for the assignment of SDCCH, TCHF, or TCHH. In this case, the previous counters are measured based on the channel type.
This is an original counter without involving any formula.