Total Sampled PDTCH Queue Lengths

Measurement Counter

R9215: CELL_RADIO_PDTCH_TOTAL_QUEUE_LEN

Description

This measurement provides the total length of the sampled PDTCH queues in a cell in a granularity period.

Unit

byte.

Measurement Point

In the granularity period, the PDTCH queue length is sampled every five seconds to obtain the total sampled PDTCH queue lengths.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential