RH3036G: CELL_INTERBSC_OUT_CELL_HO_REQ_TIMES_1800_900
Based on the MR sent by the MS, the BSC uses the handover algorithm to determine whether a handover is required. If a handover is required, and if the originating cell (current cell) and the target cell are managed by different BSCs, the BSC initiates an external inter-cell handover.
This measurement provides the total number of outgoing external inter-cell handover requests, including the requests on the SDCCH, the TCHF and the TCHH. In addition, the frequency band of the originating cell can be DCS1800 or PCS1900, and the frequency band of the target cell can be GSM900, GSM900&DCS1800, GSM850, GSM850&DCS1800, or GSM850&PCS1900.
Integer number or integer.
This counter is measured according to the following formula.
Outgoing External Inter-Cell Handover Requests (1800/1900-900/850)
= [Outgoing External Inter-Cell Handover Requests (SDCCH) (Excluding Directed Retry) (1800/1900-900/850)] +
[Outgoing External Inter-Cell Handover Requests (TCHF) (Excluding Directed Retry) (1800/1900-900/850)] +
[Outgoing External Inter-Cell Handover Requests (TCHH) (Excluding Directed Retry) (1800/1900-900/850)] +
[Outgoing External Inter-Cell Handover Requests (Directed Retry) (1800/1900-900/850)]