Average Utilization Rate of Uplink TBF Timeslots

Measurement Counter

RS9341: CELL_USER_UPLINK_AVG_TIMESLOT_UTILI_RATE

Description

This measurement provides the average utilization rate of the timeslots allocated to the uplink TBFs in transmission state in a granularity period. This measurement indicates the timeslot utilization on the uplink TBF in a cell.

Unit

%

Measurement Point

This counter is equal to the total utilization rate of sampled uplink TBF timeslots divided by the total number of sampled uplink TBFs in a granularity period.

Formula

Average Utilization Rate of Uplink TBF Timeslots = (Utilization Rate of GPRS Uplink Timeslots + Utilization Rate of EGPRS Uplink Timeslots)/(Total Number of Sampled Uplink GPRS TBFs + Total Number of Sampled Uplink EGPRS TBFs)


Huawei Proprietary and Confidential