S3109: CELL_EXT_AMR_HR_475_UP_NUM
S3110: CELL_EXT_AMR_HR_515_UP_NUM
S3111: CELL_EXT_AMR_HR_590_UP_NUM
S3112: CELL_EXT_AMR_HR_670_UP_NUM
S3113: CELL_EXT_AMR_HR_740_UP_NUM
S3117: CELL_EXT_AMR_HR_795_UP_NUM
This counter is used to measure the number of uplink frames with AMR HR of N kbit/s in the cell in the customized MR, and the coding rate should be 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s, 7.40 kbit/s, or 7.95 kbit/s.
EI_FRAME: If the EI_FRAME is contained in the MR from the BTS, it indicates that the number of uplink/downlink frames of a certain coding rate, and uplink/downlink power information are carried in the MR.
N specifies the coding rate, and the values of N are as follows: 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s, 7.40 kbit/s, and 7.95 kbit/s.
Integer number or integer.
After receiving the MR or pre-processed MR sent over the AMR channel from the BTS in the serving cell, the BSC decodes the uplink MR. If the TYPE field in the MR contains the EI_FRAME, and the EI_FRAME contains the AMR N kbit/s frames, this counter is accumulated.
Measurement object: cell
This is an original counter without involving any formula.