S3116: CELL_EXT_HR_TCH_UP_NUM
When decoding the uplink MR, the BSC checks whether the TYPE field in the MR contains the EI_FRAME. If the EI_FRAME is found and it contains the HR frames, this measurement provides the number of uplink frames among the HR frames in the customized MR.
Integer number or integer.
After receiving the MR or pre-processed MR sent from the BTS in the serving cell, the BSC decodes the uplink MR. If the TYPE field in the MR contains the EI_FRAME, and the EI_FRAME contains the HR frames, this counter is accumulated.
This is an original counter without involving any formula.