Number of Uplink Frames Among the HR Frames in the Customized MR of Cell

Measurement Counter

S3116: CELL_EXT_HR_TCH_UP_NUM

Description

When decoding the uplink MR, the BSC checks whether the TYPE field in the MR contains the EI_FRAME. If the EI_FRAME is found and it contains the HR frames, this measurement provides the number of uplink frames among the HR frames in the customized MR.

Unit

Integer number or integer.

Measurement Point

After receiving the MR or pre-processed MR sent from the BTS in the serving cell, the BSC decodes the uplink MR. If the TYPE field in the MR contains the EI_FRAME, and the EI_FRAME contains the HR frames, this counter is accumulated.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential