S3300C:CELL_HO_UL_LEV_0
S3301C:CELL_HO_UL_LEV_1
S3302C:CELL_HO_UL_LEV_2
S3303C:CELL_HO_UL_LEV_3
S3304C:CELL_HO_UL_LEV_4
S3305C:CELL_HO_UL_LEV_5
S3306C:CELL_HO_UL_LEV_6
S3307C:CELL_HO_UL_LEV_7
S3310C:CELL_HO_UL_QLTY_0
S3311C:CELL_HO_UL_QLTY_1
S3312C:CELL_HO_UL_QLTY_2
S3313C:CELL_HO_UL_QLTY_3
S3314C:CELL_HO_UL_QLTY_4
S3315C:CELL_HO_UL_QLTY_5
S3316C:CELL_HO_UL_QLTY_6
S3317C:CELL_HO_UL_QLTY_7
After receiving a valid MR from the MS or a valid pre-processed MR from the BTS, the BSC makes a handover decision. If a handover is required, the BSC measures the specific counter based on the uplink receive level (0-7) and the uplink receive quality (0-7). This counter indicates the performance of the handover in the serving cell.
Integer number or integer.
After receiving a valid MR from the MS or a valid pre-processed MR from the BTS, the BSC makes a handover decision. If a handover is required, the specific counter is incremented by one based on the uplink receive level and the uplink receive quality.
This is an original counter without involving any formula.